CASE STUDY

SeaShield 80 & Denso Glass Outerwrap System Protects Sea Outfall Pipe

Subsea & Splash Zone Coatings

Project Data

LocationKirk Michael, Isle of Man
ClientManx Utilities
ConsultantHyder Consulting
Contractor JCK
DateSeptember 2014
ProductsSeaShield 80™ System, Denso Glass Outerwrap 70™

Project Details

Three new joints on a Sea Outfall Pipe required protection in an extremely severe environment.

A Denso SeaShield 80 System – consisting of Denso Paste S105, Densyl Mastic, Denso Marine Piling Tape and Densoclad 70 Tape, with an extra outerwrap of Denso Glass Outerwrap 70 – was used to provide the necessary protection.